[ 1 ]  [ 2 ]  [ 3 ]  [ 4 ]  [ 5 ]  [ 6 ]  [ 7 ]  [ 8 ]  [ 9 ]  [ back ] 


Once the fluence spectrum Φ(ε) (cm–2) is known (by experimental measurements or through calculations) the effective dose E can be calculated using the following expression:

E = fE(ε) · Φ(ε) · d(ε)
(6)

and the ambient dose equivalent can be calculated in a similar way:

H* = fH*(ε) · Φ(ε) · d(ε)
(7)

When using these sets of conversion coefficients for calculations, you should cite paper [22].


Giuseppe Battistoni; INFN, Milano
Stefan Roesler; CERN, Geneva


Last updated: 10th of October, 2008